Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation: Cardiovascular Imaging
Search: search_blue_button Advanced Search
Circulation: Cardiovascular Imaging. 2008;1:41-49
doi: 10.1161/CIRCIMAGING.107.763110
CLINICAL PERSPECTIVE
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Castro, S.
Right arrow Articles by Pandian, N. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Castro, S.
Right arrow Articles by Pandian, N. G.
Related Collections
Right arrow Other heart failure
Right arrow CT and MRI
Right arrow Echocardiography
Right arrowRelated Article

Original Articles

Tomographic Left Ventricular Volumetric Emptying Analysis by Real-Time 3-Dimensional Echocardiography

Influence of Left Ventricular Dysfunction With and Without Electrical Dyssynchrony

Stefano De Castro, MD; Francesco Faletra, MD; Emanuele Di Angelantonio, MD; Cristina Conca, MD; Andrea Marcantonio, MD; Marco Francone, MD, MSc; Domenico Cartoni, MD; Francesca Mirabelli, MD; Carlo Gaudio, MD; Stefano Caselli, MD; Iacopo Carbone, MD; Angelo Auricchio, MD and Natesa G. Pandian, MD

From La Sapienza, University of Rome, Rome, Italy (S.D.C., A.M., M.F., D.C., F.M., C.G., S.C., I.C); Cardiocentro Ticino, Lugano, Switzerland (F.F., C.C., A.A.); Department of Public Health and Primary Care, University of Cambridge, Cambridge, England (E.D.A.); and Tufts–New England Medical Center, Boston, Mass (N.G.P.).

Correspondence to Stefano De Castro, MD, Department of Cardiovascular, Respiratory, and Morphological Sciences, La Sapienza, University of Rome, Viale del Policlinico, 155, 00161 Rome, Italy. E-mail stefano.decastro{at}uniroma1.it

Received January 24, 2007; accepted May 13, 2008.


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
Background— The sequence of left ventricular (LV) systolic emptying is not completely understood. Using real-time 3-dimensional echocardiography, we investigated this sequence and LV synchronicity in physiological and pathological conditions.

Methods and Results— The study population consisted of 116 healthy volunteers, 20 top-level athletes, 35 patients with LV dysfunction, and 84 patients with LV dysfunction and left bundle-branch block (LBBB). We subdivided the LV into 16 volumetric segments for regional analysis and into apical, middle, and basal regions to calculate the mean of end-systolic times and the time to minimum systolic volume of each region. In healthy volunteers and in top-level athletes, the emptying systolic times increased smoothly from apex to base. These differences determined an apex-to-base time gradient in the LV emptying sequence. In patients with LV dysfunction and without LBBB, this gradient was maintained with a relatively higher LV dyssynchrony. However, in patients with LV dysfunction and LBBB, there was no clear sequence in LV emptying volumes, and this group had the highest LV dyssynchrony.

Conclusions— Real-time 3-dimensional echocardiography tomographic slicing of the LV enables accurate analysis of LV emptying in physiological conditions and in conditions of LV dysfunction with and without electrical dyssynchrony. Progressive dilation of LV produces deterioration in LV synchronicity. However, it is the presence of LV dysfunction in combination with LBBB that determines the loss of the apex-to-base time gradient in LV emptying.

Key Words: arrhythmia • echocardiography • heart failure • remodeling


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
Detailed understanding of left ventricular (LV) functional dynamics has become more important as new options to treat LV dysfunction become available. Several studies using different noninvasive and invasive imaging techniques, such as 2-dimensional (2D) tissue Doppler imaging (TDI),1–3 2D strain by speckle tracking,4,5 magnetic resonance imaging (MRI),6,7 and implanted ultrasonic crystals,8 have attempted to assess global and regional myocardial motion. In particular, some have focused on the mechanisms that control the regional timing of myocardial contraction and demonstrated that mechanical events parallel the apex-to-base direction of electrical activation.9,10 Although myocardial contraction is principally circumferential,11,12 a contraction wave along the axial direction is important because it influences LV ejection efficiency; by spreading from apex to base during the ejection, the contraction wave propels the blood toward the ventricular outflow tracts, preventing at the same time a drift of blood toward the apex. To our knowledge, no available technique has examined the effect, in the human heart, of myocardial contraction on LV emptying, principally because of technical limitations and the complex architecture of the myocardium. Moreover, recent studies of intracavitary blood vortices13 and myocardial fiber architecture14 suggest that counterdirectional movements of a vortex produce suction and expulsion forces. These movements seem to maximize the efficiency of cardiac performance in healthy subjects while ensuring an efficient distribution of regional stresses and strains 15. With an altered ventricular shape resulting from cardiac remodeling, regional myocardial dysfunction or asynchronous conduction can distort the efficacy of the loading and expulsion dynamics.16,17 The temporal gradient of LV emptying in the axial direction during systole has not yet been analyzed in a large sample of normal individuals and in LV dysfunctional patients with and without left bundle-branch block (LBBB). Such knowledge would enhance understanding of LV systolic performance and potentially have a clinical impact.

Clinical Perspective see p 41

The introduction of real-time 3-dimensional (3D) echocardiography has allowed evaluation of the magnitude of spatial and temporal changes in global and regional volumetric LV function.18–21

In this study, we investigated (1) the sequence of LV systolic emptying in normal individuals and in top-level athletes; (2) the effect of LV dysfunction on LV systolic emptying; (3) the effect of LV dysfunction and electrical dyssynchrony in LV systolic emptying; and (4) the distribution of dyssynchrony, in regional volumetric terms, in all sample subjects. To do so, we divided the LV into 3 major annular tomographic regions (apical, middle, and basal) using a real-time 3D echocardiography machine equipped with commercially available software.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
The study was performed at 2 centers: La Sapienza University Hospital, Rome, Italy, and the Cardiocentro Ticino, Lugano, Switzerland. All subjects gave written informed consent for the study. The research ethics committees of the centers approved the study. The authors had full access to the data and take full responsibility for the integrity of the data. All authors have read and agree to the manuscript as written.

Study Population and Patient Selection
The study population consisted of 267 selected subjects: 116 healthy volunteers; 22 top-level athletes; 39 patients affected by LV dysfunction and narrow QRS; and 90 patients affected by LV dysfunction and LBBB. Selection criteria and classification were based on clinical history, blood pressure, clinical examination, ECG, and 2D/Doppler echocardiographic studies.

The 116 healthy volunteers (75 men) satisfied the following criteria: normal physical examination, normal blood pressure (<135 mm Hg and <80 mm Hg), normal ECG findings, no history of chest pain and dyspnea, no diabetes, and normal 2D echocardiographic and Doppler examination. None of the subjects was on medication. Subjects with evidence of heart disease, hypertension, or other systemic disorders were excluded. The 22 top-level athletes were professional soccer players in the Italian first division (who train at least 20 h/wk). Within the LV dysfunction and narrow QRS group, 24 patients were diagnosed with ischemic dilated cardiomyopathy and 15 with idiopathic dilated cardiomyopathy. Within the LV dysfunction and LBBB group, 71 patients were diagnosed with ischemic dilated cardiomyopathy and 19 with idiopathic dilated cardiomyopathy. Twenty-nine of 129 LV dysfunctional patients with and without LBBB had a history of myocardial infarction. All patients had undergone coronary angiography and/or multislice CT scan within the previous 6 months. The diagnosis of dilated cardiomyopathy was based on M-mode and 2D/Doppler echocardiographic examination demonstrating an end-diastolic diameter >3.2 cm/m2 and LV ejection fraction (LVEF) <40%.22 Idiopathic dilated cardiomyopathy patients had normal coronary arteries, whereas ischemic patients had had a documented abnormal coronary angiography and/or multislice computed tomographic scan. General exclusion criteria were any of the following: atrial fibrillation, poor echocardiographic acoustic window, or significant mitral or aortic regurgitation (>2+/4+).

Two-Dimensional Echocardiography
Two-dimensional echocardiography was performed by 2 expert cardiologists using commercial ultrasound machines (Sonos 7500 or i.E33, Philips Medical Systems, Andover, Mass) with an S5 probe (2 to 4 MHz). A complete examination of each subject included 2D and Doppler analysis. The LVEF was estimated in 4- and 2-chamber windows by the modified Simpson’s method.23

Three-Dimensional Echocardiography
Real-time 3D echocardiography was performed by 2 expert cardiologists using an i.E33 Live 3D echo (Philips Medical Systems) equipped with the x4 transducer. The acquisition time was recorded from the apical 4-chamber view. To encompass the entire LV cavity within the pyramidal scan volume, data sets were acquired by the wide-angled mode, whereby 4 or 7 wedge-shaped subvolumes (93°x21°) were acquired during a single breath hold. Acquisition of each subvolume was triggered by the ECG R wave of every heartbeat. LV end-diastolic volume and end-systolic volume were evaluated with the use of semiautomatic frame-by-frame LV endocardial contours. These were corrected manually when necessary with 4-dimensional (4D) LV analysis 2.0 software (TomTec, Unterschleissheim, Germany). The papillary muscles were included in the LV cavity evaluation. The time taken for the offline quantitative analysis of the 3D data sets was also recorded.

Regional Volumetric Emptying and Synchronicity Analysis
All measurements were performed by 2 investigators experienced in the interpretation of cardiac images, who were blinded to each other’s results. Three-dimensional data were analyzed offline with the use of a contour-tracing algorithm over a complete cardiac cycle. Graphs displaying volumetric changes in the whole cardiac cycle were assessed on the basis of 3D data. Three-dimensional models of the LV were generated and subdivided into 16 volumetric segments for regional analysis so that the volume curves could be analyzed for the complete LV and for each segment individually. The surface patches of the LV cavity reconstruction were linked to the center of gravity of the 3D shell to create pyramidal-shaped regional volumes. A center of gravity was used that represented the average of the centers of gravity of all phases (Figure 1a).


Figure 1763110
View larger version (11K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1. Diagram of ventricle showing pyramid viewed by the software for calculating the regional volume (A), and images illustrating the final phase of echocardiographic (B) and CMR (C) analysis techniques.

 
After classification in a 16-segment model, displayed in a segmental bull’s eye map, each regional time-volume curve was analyzed throughout the cardiac cycle. Then the time to minimum systolic volume was measured from the onset of the cardiac cycle (Q wave of ECG signal) to the minimum volume for each segment. Subsequently, the LV segments were grouped into 3 major annular tomographic regions: basal (n=6), middle (n=6), and apical (n=4) (Figure 2). This was done to derive the following values for each of the selected segments: mean end-systolic time (MES%) and time to minimum systolic volume and the standard deviation.


Figure 2763110
View larger version (47K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2. LV regional volume-time curves (right) showing time to minimum systolic volume for the 3 major annular tomographic regions.

 
The systolic dyssynchrony index (SDI%) is a global parameter describing dyssynchrony of the whole ventricle. In our study, we used, in both global and in regional volumetric terms, a definition of SDI% as the standard deviation of the time taken to reach minimum systolic volume for each annular tomographic region. The differentiation between LV synchrony or dyssynchrony was done on the basis of a cutoff value of 5%, as previously reported.24 All data were expressed as a percentage of the cardiac cycle length.

Three-Dimensional Echocardiography Validation Protocol
In 20 of 116 healthy volunteers, real-time 3D echocardiography and cardiac magnetic resonance (CMR) were performed, on the same day, to validate LV emptying analysis. CMR was performed with a commercially available 1.5-T scanner with highly performing gradients (Siemens Avanto; Siemens Medical Solutions, Erlangen, Germany) with the use of a phased-array cardiac coil and a vectorcardiographic gating system. ECG-gated turbo spin-echo images were initially acquired as anatomic reference during a 14-second breath hold to identify the horizontal long axis of the LV and to obtain images in 8 rotated planes around the long axis at 22.5° steps. Steady-state free-procession gradient-echo cine mode (repetition time 2xRR interval, echo time 64, matrix 138x256, flip angle 60°) was then used to acquire dynamic cine loops ({approx}20 frames per cardiac cycle) of radial long-axis views of the LV (10-mm slice thickness; 1.4- to 1.8-mm in-slice resolution) and short-axis images covering the entire LV from the mitral valve plane to the apex (10-mm slice thickness, no gaps). All images were acquired during a 10- to 15-second breath hold and digitally archived to a picture archiving and computerized system and a DVD for offline analysis of LV function. The offline analysis was performed in 6 of the 8 acquired long-axis planes with the same algorithm and same software as for the 3D echo images with 4D LV analysis 2.0 (TomTec). The surface patches of the LV cavity reconstruction were linked to the center of gravity of the 3D shell to create pyramidal-shaped regional volumes. A center of gravity was used that represented the average of the centers of gravity of all phases (Figure 1).

Statistical Analysis
Nominal variables are expressed as percentages and compared with the {chi}2 test. Continuous variables are expressed as mean and standard deviation. Comparisons between patient groups were assessed by ANCOVA after adjustments for age and sex and with the use of the Bonferroni correction for multiple comparisons. Regional volumetric analysis was performed with the use of linear mixed-effect models with random intercept to take into account correlations among values within individuals while simultaneously analyzing all 3 regions. Pearson’s correlation and linear regression analyses were used to assess associations between SDI and MES and clinical and echocardiographic parameters. Interobserver and intraobserver agreements were assessed by the Bland-Altman method, expressing the average difference between readings with 95% CI. Differences between MRI and echocardiography were assessed by paired-sample t test and 95% CI. A value of P<0.05 was considered significant. All analyses were performed with the use of STATA software (release 10, Stata Corporation, College Station, Tex).


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
Feasibility
The acquisition of real-time 3D echocardiography data sets was feasible in all patients except 12 (heart size exceeded that of the pyramidal scan volume in 7 cases, and there were technical problems in the management of DICOM data acquired in 5 cases). In the remaining population (n=255), all apical 4-chamber views allowed an optimal 3D data set for performing LV analysis. The acquisition time was {approx}8 seconds for each volume scan, and the LV global and segmental quantitative evaluation time was 10 to 20 minutes. Semiautomatic endocardial border LV detection was, in most cases, corrected manually. Offline tomographic regional analysis (basal, middle, and apical) of the LV required a prolonged evaluation time compared with a simple global LV functional evaluation, as previously reported.25

Validation of 3D LV Emptying Analysis
Comparisons between 3D echo and MRI performed in 20 healthy volunteers showed very high agreement. The absolute difference for global LV MES% on the total 16 segments was –2.3 (95% CI, –7.5 to 2.8), and for global LV SDI % it was –0.08 (95% CI, –0.75 to 0.60). For tomographic LV emptying, regional MES% analysis was –1.7 (95% CI, –7.2 to 3.9), –1.3 (95% CI, –7.0 to 4.4), and –1.2 (95% CI, –7.0 to 4.7) for the apical, middle, and basal regions, respectively. For LV emptying, regional SDI% analysis was 0.48 (95% CI, –0.29 to 1.25), –0.13 (95% CI, –1.04 to 0.77), and 0.37 (95% CI, –0.78 to 1.54) for apical, middle, and basal regions, respectively.

Interobserver and Intraobserver Variability
Fifty healthy volunteers, with adequate acoustic windows, were selected for reliability analysis for SDI% and MES% measures. As Figure 3 shows, the Bland-Altman analyses yielded an excellent agreement with a mean±SD difference for intraobserver SDI and MES of 0.02±0.44 and 0.34±0.92, respectively, and with a mean±SD difference for interobserver SDI and MES of –0.04±0.52 and –0.11±0.97.


Figure 3763110
View larger version (13K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3. Bland-Altman plots for intraobserver (left) and interobserver (right) variability for SDI% and MES%.

 
Global LV Function
As expected, healthy volunteers and the top-level athletes were younger than LV dysfunctional patients with and without LBBB (Table 1). Compared with healthy volunteers, the global end-diastolic volume and end-systolic volume rose gradually from top-level athletes to LV dysfunctional patients without LBBB (P<0.001) and with LBBB (P<0.001). With regard to the value of global LVEF, there was no significant difference between healthy volunteers and top-level athletes, whereas there was, as expected, a significant difference in LV dysfunctional patients with and without LBBB (P<0.001). In terms of stroke volume, there was an increase in the value for top-level athletes in comparison with healthy volunteers, and there was a significant decrease in that of the other groups. The comparison between LV dysfunctional patients with and without LBBB did not show any difference in terms of end-diastolic volume, end-systolic volume, and stroke volume except for a mild reduction in EF in those with LBBB.


View this table:
[in this window]
[in a new window]

 
Table 1. Summary Data
 
The MES% of 16 segments was lower, but not significantly so, in top-level athletes than in healthy volunteers (Table 2). Compared with the latter, the value for LV dysfunctional patients without LBBB was higher but not significantly so, whereas the value for the LV dysfunctional patients with LBBB was significantly higher (P<0.001).


View this table:
[in this window]
[in a new window]

 
Table 2. Global Offline Analysis of the LV by Real-Time 3D Echocardiography
 
The SDI% value of 16 segments was similar between healthy volunteers and top-level athletes, whereas it was significantly higher for both groups of LV dysfunctional patients (with the highest value for those with LBBB; P<0.001).

There was a highly significant negative correlation between SDI% and EF% (r=–0.79; P<0.001) even after adjustment for age and sex (age- and sex-adjusted t statistics, –9.48). On regression analysis, 72% of the SDI% variability was explained by LBBB, history of myocardial infarction, and EF. In particular, the presence of LBBB, myocardial infarction, and a 10% decrease in EF were associated with a 4.3-fold (95% CI, 3.35 to 5.22), 1.78-fold (95% CI, 0.64 to 2.72), and 1.14-fold increase in SDI%, respectively.

Regional Volumetric Analysis
As shown in Figure 4A, in the group of healthy volunteers and top-level athletes, there was a statistically significant difference between the 3 annular tomographic regions of the LV in regard to the mean end-systolic time of each volume-time curve (MES%). In particular, the emptying systolic time increased in a smooth progression from the apical to the basal regions. This progression was more marked for the top-level athletes. These time differences determined a gradient, in terms of time, from the apex to the base in the LV emptying sequence.


Figure 4763110
View larger version (17K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4. Mean values and 95% CIs for MES% (A) and SDI% (B) for the 3 major annular tomographic regions for all groups.

 
In regard to the dyssynchrony index (SDI%), there was a statistically significant difference between the 3 annular tomographic regions of the LV. For both healthy volunteers and top-level athletes, the lowest value of dyssynchrony was found in the apical regions. This was probably due to a number of concurrent factors: (1) the smaller number of segments involved (4 apical and 6 middle and basal); and (2) the smaller volume contained by the apical annular tomographic region compared with the remaining volumes.

In regard to patients with LV dysfunction without LBBB, although the apex-to-base progression sequence was evident, the extended emptying time for the basal compared with the apical and middle segments was statistically significant (P<0.001). Of particular interest, the values of the dyssynchrony index exceeded the accepted cutoff value of 5%.

In regard to patients with LV dysfunction and LBBB, there was a significant difference between the middle and basal segments in terms of the aforementioned extended emptying times. However, the shift in the apical values, stemming from the asynchronous electrical activation associated with LBBB, resulted in the loss of the smooth upward gradient (Table in the online-only Data Supplement).

In regard to SDI%, although all 3 annular tomographic ventricular regions were affected, we found the highest value for the apical region. This showed a statistically significant difference compared with the middle and the basal regions (Figure 4B).


    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
Using the 3-major-tomographic-region model of the LV, we investigated the sequence and time gradient of the mean end-systolic time between the 3 regions, from the apex to the base of the LV. To validate 3D echocardiographic findings, we compared tomographic LV volumetric emptying analysis by 3D echocardiography with MRI in 20 healthy volunteers, using the same algorithm and quantitative software. These results demonstrated a very high degree of concordance between the 2 different techniques. We used commercially available software to extrapolate the time to minimum systolic volume, the mean end-systolic time, and the standard deviation of each LV volumetric region. Nesser et al26 confirmed the validity of using such software through their analysis of regional volumetric assessment of the LV by real-time 3D echocardiography and CMR.

Our study is the first on the human heart using regional volumetric analysis by real-time 3D echocardiography that demonstrates that, in healthy volunteers and in top-level athletes, there is a peristaltic emptying of the LV from the apex to the base. These data confirm what logic would suggest, ie, there is a proper sequence with a regular time gradient that determines the correct and efficacious emptying of the LV, moving the blood from the apex to the aortic valve.

We also evaluated the influence of LV global function in all groups. The expected progressive increment in mean end-systolic time, time to minimum systolic volume, and standard deviation from top-level athletes to LV dysfunctional patients with LBBB confirms the usefulness of this technique in evaluation of LV function. Although the normal ventricle works in an efficient manner to distribute stress and strain uniformly, an altered ventricle resulting from cardiac remodeling, regional myocardial dysfunction, or asynchronous conduction determines wall motion abnormalities, which are responsible for the degradation of the synchronicity of LV emptying.

Although LV dysfunctional patients without LBBB maintain the apex-to-base time gradient, in the presence of an increased SDI%, the extended emptying time for the basal compared with the apical and middle regions may indicate a progressive deterioration in LV systolic performance. This may reasonably lead us to suppose that, in altered LVs, the basal regions require more time to empty their already major volume of blood than do the other regions. We found the same basal/middle region extended emptying time in LV dysfunctional patients with LBBB. It is precisely the presence of the electrical dyssynchrony that is responsible for the delay in the activation of the apical segments, as shown by the higher value of SDI% for patients with LBBB than for those without LBBB. The information pertaining to LV dysfunction and LBBB patients confirms that, in the presence of electrical dyssynchrony, some LV regions delay their contracting motion, resulting in an uncoordinated and irregular LV emptying. They produce an increased ejection time, a reduced stroke volume, and an inefficient expulsion dynamic. As regression analysis of our data shows, LBBB is the main factor in determining an increased dyssynchrony index (SDI%) and the loss of LV emptying sequence, followed by the presence of myocardial infarction and a reduced EF.

Furthermore, our study highlights another aspect that is the subject of much current research. It shows that, in the presence of electrical dyssynchrony, although all 3 tomographic regions are affected by mechanical dyssynchrony, the region most severely affected is the apical one. This finding is particularly important because no widely available/used techniques for assessing dyssynchrony can analyze the apical region. Doppler imaging has methodological limitations relating to its longitudinal velocity, and its strain and strain rate are prone to angle-related errors.3 Helm et al,27 using 3D MRI, demonstrated that longitudinal strains were less sensitive than circumferential strains as an indicator of dyssynchrony. Again, apical regions cannot be assessed by TDI because of the limited movement of the apex and unfavorable angle of incidence of apical myocardial motion with respect to the transducer position. Consequently, most investigators use a 2-, 6-, or 12-segment model for assessing intraventricular dyssynchrony.28–30

Our study analyzed the regional volume–time curves of the LV but did not evaluate the whole myocardial motion in time sequence. This relatively easy 3D method provides information for the timely and accurate assessment of LV emptying. This concrete result adds a simple technique to the range of procedures that analyze myocardial motion rather than LV volume emptying.

Assessment of mechanical activation and contraction by conventional imaging methods is complex. Although they provide high temporal resolution, TDI, strain, and strain rate present limitations because of the complex architecture of the myocardium. Sengupta et al31 showed that differences in timing of contraction exist between segments and also between longitudinal and circumferential shortening within the same segment. Recently, 2D strain by speckle tracking has been used to overcome the limitations of Doppler-derived data.5 This new technique provides angle-independent information on motion and deformation in any direction of a cardiac coordinate system. It can analyze longitudinal and transverse strains by apical views and circumferential and radial strains in the parasternal short-axis plane. It can also evaluate LV torsion.32 Several studies have demonstrated its validity with sonomicrometry and tagged MRI.5,33

The 2 most common MRI methods used by researchers for measuring myocardial motion are tagging34 and phase-contrast velocity mapping.35,36 The latter quantifies wall motion with a sensitivity comparable to implanted ultrasonic crystals and displays high correlation for myocardial velocities with TDI measurements in healthy volunteers. However, this technique is time consuming, is not widely available, and does not provide information on the LV emptying sequence.

The advantage of LV regional volumetric analysis using real-time 3D echocardiography consists of a reliable, straightforward, and reproducible assessment of the temporal sequence of LV emptying. This strengthens the case for using real-time 3D echocardiography because it enables volumetric assessment rather than resorting to parameters influenced by distortion and translation of LV wall motion. Indeed, a recent study, performed in healthy volunteers using different TDI procedures, demonstrated that systolic LV motion seemed to be significantly more synchronous in the radial direction than in the long axis.27 This confirms that assessment of mechanical synchronicity by conventional imaging methods is complex, considering the particular 3D pattern of ventricular contraction. For this reason, real-time 3D echocardiography has been used to quantify global LV mechanical dyssynchrony in congestive heart failure patients with moderate to severe symptoms and substantial LV dysfunction.24

Our study has some technical limitations. First, in 7 patients, we were unable to encompass the entire LV because of the extremely enlarged chamber. Second, there is the issue of a low frame rate, which is {approx}16 to 20 Hz. However, the frame rate is the same as that accepted with CMR studies. To conduct offline 3D analysis, it is necessary to have optimal acoustic windows that guarantee clear definition of the LV endocardial borders. For this reason, we chose to select the study population because, in a daily clinical scenario, {approx}20% of consecutive patients cannot be evaluated in a reproducible manner.

Despite a low temporal resolution, we consistently found a time gradient from the apical to the middle and basal regions in the healthy volunteers and top-level athletes.

With regard to apex-to-base LV emptying analysis, our research is still ongoing. This first stage has shown that it is a feasible and validated technique that provides information on physiopathological changes in LV function. In the current stage of our research, we are applying this analysis in end-stage heart failure patients who can benefit from resynchronization therapy.


    Conclusions
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
Three-dimensional tomographic analysis of the LV enables accurate analysis of LV emptying in physiological conditions and in those of LV dysfunction with and without electrical dyssynchrony. Progressive dilation of LV produces deterioration in LV synchronicity. However, it is the presence of LV dysfunction in combination with LBBB that determines the loss of the apex-to-base time gradient in LV emptying. Determination of whether this gradient could be utilized as an index for optimizing selection of candidates or whether patients can recover the normal temporal sequence of LV emptying after cardiac resynchronization therapy is a long process that requires considerable effort in terms of patient selection, data collection and analysis, and proper follow-up. Real-time 3D echocardiography is a relatively simple procedure and a robust method for investigating global and regional LV dynamics.


    Acknowledgments
 
Sources of Funding

This research was supported in part by Banca d'Italia.

Disclosures

None.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 References
 
1. D'hooge J, Heimdal A, Jamal F, Kukulski T, Bijnens B, Rademakers F, Hatle L, Suetens P, Sutherland GR. Regional strain and strain rate measurements by cardiac ultrasound: principles, implementation and limitations. Eur J Echocardiogr. 2000; 1: 154–170.[Abstract/Free Full Text]

2. Sun JP, Popovic ZB, Greenberg NL, Xu XF, Asher CR, Stewart WJ, Thomas JD. Noninvasive quantification of regional myocardial function using Doppler-derived velocity, displacement, strain rate, and strain in healthy volunteers: effects of aging. J Am Soc Echocardiogr. 2004; 17: 132–138.[CrossRef][Medline]

3. Urheim S, Edvardsen T, Torp H, Angelsen B, Smiseth OA. Myocardial strain by Doppler echocardiography: validation of a new method to quantify regional myocardial function. Circulation. 2000; 102: 1158–1164.[Abstract/Free Full Text]

4. Korinek J, Kjaergaard J, Sengupta PP, Yoshifuku S, McMahon EM, Cha SS, Khandheria BK, Belohlavek M. High spatial resolution speckle tracking improves accuracy of 2-dimensional strain measurements: an update on a new method in functional echocardiography. J Am Soc Echocardiogr. 2007; 20: 165–170.[CrossRef][Medline]

5. Amundsen BH, Helle-Valle T, Edvardensen T, Torp H, Crosby J, Lyseggen E, Stoylen A, Ihlen H, Lima JA, Smiseth OA, Slordahl SA. Noninvasive myocardial strain measurement by speckle tracking echocardiography validation against sonomicrometry and tagged magnetic resonance imaging. J Am Coll Cardiol. 2006; 47: 789–793.[Abstract/Free Full Text]

6. Edvarsen T, Gerber BL, Garot J, Bluenke DA, Lima JA, Smiseth OA. Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans: validation against three-dimensional tagged magnetic resonance imaging. Circulation. 2002; 106: 50–56.[Abstract/Free Full Text]

7. Jung B, Markl M, Foll D, Henning J. Investigating myocardial motion by MRI using tissue phase mapping. Eur J Cardiothorac Surg. 2006; 29S: S150–S157.[Abstract/Free Full Text]

8. Goetz WA, Lansac E, Lim HS, Weber PA, Duran CM. Left ventricular endocardial longitudinal and transverse changes during isovolumic contraction and relaxation: a challenge. Am J Physiol. 2005; 289: H196–H201.

9. Wyman BT, Hunter WC, Prinzen FW, Faris OP, McVeigh ER. Effects of single- and biventricular pacing on temporal and spatial dynamics of ventricular contraction. Am J Physiol. 2002; 282: H372–H379.

10. Kim B, Starc V. Contraction wave in axial direction in free wall of guinea pig left ventricle. Am J Physiol. 2004; 287: H755–H759.

11. Sonnenblick EH, Ross J Jr, Covell JW, Spotnitz HM, Spiro D. The ultrastructure of the heart in systole and diastole: changes in sarcomere length. Circ Res. 1967; 21: 423–431.[Abstract/Free Full Text]

12. Greenbaum RA, Ho SY, Gibson DG, Becker AE, Anderson RH. Left ventricular fiber architecture in man. Br Heart J. 1981; 45: 248–263.[Abstract/Free Full Text]

13. Gharib M, Rammbod E, Kheradvar A, Shan DJ, Dabiri JO. Optimal vortex formation as an index of cardiac health. Proc Natl Acad Sci U S A. 2006; 103: 6305–6308.[Abstract/Free Full Text]

14. Torrent-Guasp F, Ballester M, Buckberg GD, Carreras F, Flotats A, Carrio I, Ferreira A, Samuels LE, Narula J. Spatial orientation of the ventricular muscle band: physiologic contribution and surgical implications. J Thorac Cardiovsc Surg. 2001; 122: 389–392.[Free Full Text]

15. Vendelin M, Bovendeerd PH, Engelbrecht J, Arts T. Optimizing ventricular fibers: uniform strain or stress, but not ATP consumption, leads to high efficiency. Am J Physiol. 2002; 283: H1072–H1081.

16. Helm PA, Younes L, Beg MF, Ennis DB, Leclercq C, Faris OP, McVeigh E, Kass D, Miller MI, Winslow RL. Evidence of structural remodeling in the dyssynchronous failing heart. Circ Res. 2006; 98: 125–132.[Abstract/Free Full Text]

17. Prinzen FW, Peschar M. Relation between the pacing induced sequence of activation and left ventricular pump function in animals. Pacing Clinc Electrophysiol. 2002; 25: 484–498.[CrossRef]

18. Monaghan MJ. Role of real time 3D echocardiography in evaluating the left ventricle. Heart. 2006; 92: 131–136.[Free Full Text]

19. Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ. Three-dimensional echocardiography. J Am Coll Cardiol. 2006; 48: 2053–2069.[Abstract/Free Full Text]

20. Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Galuschky C, Schummers G, Lang RM, Nesser A. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation. 2006; 114: 654–661.[Abstract/Free Full Text]

21. Pang BSF, Kot BCW, Ying M. Three-dimensional ultrasound volumetric measurements: is the largest number of image planes necessary for outlining the region-of-interest? Ultrasound Med Biol. 2006; 32: 1193–1202.[CrossRef][Medline]

22. Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I, Silverman NH, Tajik AJ; American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-dimensional Echocardiograms. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. J Am Soc Echocardiogr. 1989; 2: 358–367.[Medline]

23. Schiller NB, Acquatella H, Ports TA, Drew D, Goerke J, Ringertz H, Silverman NH, Brundage B, Botvinick EH, Boswell R, Carlsson E, Parmley WW. Left ventricular volume from paired biplane two-dimensional echocardiography. Circulation. 1979; 60: 547–555.[Abstract/Free Full Text]

24. Kapetanakis S, Kearney MT, Siva A, Gall N, Cooklin M, Monaghan MJ. Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony. Circulation. 2005; 112: 992–1000.[Abstract/Free Full Text]

25. De Castro S, Caselli S, Maron M, Pelliccia A, Cavarretta E, Maddukuri P, Cartoni D, Di Angelantonio E, Kuvin JT, Patel AR, Pandian NG. Left ventricular remodelling index (LVRI) in various patho-physiologic conditions: a real-time three-dimensional echocardiographic study. Heart. 2007; 93: 205–209.[Abstract/Free Full Text]

26. Nesser HJ, Sugeng L, Corsi C, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Schummers G, Lang RM, Mor-Avi V. Volumetric analysis of regional left ventricular function with real-time 3D echocardiography: validation by magnetic resonance and clinical utility testing. Heart. 2007; 93: 572–578.[Abstract/Free Full Text]

27. Helm RH, Leclercq C, Faris OP, Ozturk C, McVeigh E, Lardo AC, Kass DA. Cardiac dyssynchrony analysis using circumferential versus longitudinal strain: implications for assessing cardiac resynchronization. Circulation. 2005; 111: 2760–2767.[Abstract/Free Full Text]

28. Popovic ZB, Grimm RA, Perlic G, Chinchoy E, Geraci M, Sun JP, Donal E, Xu XF, Greenberg NL, Wilkoff BL, Thomas JD. Noninvasive assessment of cardiac resynchronization therapy for congestive heart failure using myocardial strain and left ventricular peak power as parameters of myocardial synchrony and function. J Cardiovasc Electrophysiol. 2002; 13: 1203–1208.[CrossRef][Medline]

29. Yu CM, Chau E, Sanderson JE, Fan K, Tang MO, Fung WH, Lin H, Kong SL, Lam YM, Hill MR, Lau CP. Tissue Doppler echocardiographic evidence of reverse remodeling and improved synchronicity by simultaneously delaying regional contraction after biventricular pacing therapy in heart failure. Circulation. 2002; 105: 438–445.[Abstract/Free Full Text]

30. Bax JJ, Abraham T, Barold SS, Breithardt OA, Fung JW, Garrigue S, Gorcsan J III, Hayes DL, Kass DA, Knuuti J, Leclercq C, Linde C, Mark DB, Monaghan MJ, Nihoyannopoulos P, Schalij MJ, Stellbrink C, Yu CM. Cardiac resynchronization therapy, part 1: issues before device implantation. J Am Coll Cardiol. 2005; 46: 2153–2167.[Abstract/Free Full Text]

31. Sengupta PP, Khandheria BK, Korinek J, Wang J, Jahangir A, Seward JB, Belohlevek M. Apex-to-base dispersion in regional timing of left ventricular shortening and lengthening. J Am Coll Cardiol. 2006; 47: 163–172.[Abstract/Free Full Text]

32. Notomi Y, Lysyansky P, Setser RM, Shiota T, Popovic ZB, Martin-Miklovic MG, Weaver JA, Oryszak SJ, Greenbverg NL, White RD, Thomas JD. Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging. J Am Coll Cardiol. 2005; 45: 2034–2041.[Abstract/Free Full Text]

33. Cho GY, Chan J, Leano R, Strudwick M, Marwick TH. Comparison of two-dimensional speckle and tissue velocity based strain and validation with harmonic phase magnetic resonance imaging. Am J Cardiol. 2006; 97: 1661–1666.[CrossRef][Medline]

34. Jung B, Markl M, Foll D, Henning J. Investigating myocardial motion by using MRI tissue phase mapping. Eur J Cardiothorac Surg. 2006; 29S: S150–S157.[Abstract/Free Full Text]

35. Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP. Human heart: tagging with MR imaging: a method for non-invasive assessment of myocardial motion. Radiology. 1988; 169: 59–63.[Abstract/Free Full Text]

36. Pelc LR, Sayre J, Yun K, Castro LJ, Herfkens RJ, Miller DC, Pelc NJ. Evaluation of myocardial motion tracking with cine-phase contrast magnetic resonance imaging. Invest Radiol. 1994; 29: 1038–1042.[CrossRef][Medline]


 

CLINICAL PERSPECTIVE

Detailed understanding of left ventricular (LV) functional dynamics has become more important as new options to treat LV dysfunction become available. We performed a study, using real-time 3-dimensional echocardiography, investigating the time gradient of LV emptying in the axial direction during systole in a large sample of normal individuals and in LV dysfunctional patients with and without left bundle-branch block. We demonstrated that, in physiological conditions, there is a proper sequence with a regular time gradient that determines the correct and efficacious emptying of the LV, moving the blood from the apex to the aortic valve. Conversely, progressive LV dilation and the presence of LV electrical dyssynchrony produce delay, resulting in uncoordinated and irregular LV emptying. These conditions determine an increase in the ejection time, a reduction in stroke volume, and an inefficient expulsion dynamic. The presence of left bundle-branch block is the main factor in determining an increased dyssynchrony index and the loss of LV emptying sequence. This study demonstrates that real-time 3-dimensional echocardiography is a feasible and validated technique that can provide new and clinically relevant information on physiopathological changes in LV function. We believe that this type of analysis may be useful in evaluating patients in end-stage heart failure who might benefit from resynchronization therapy or in assessing the effects of different therapeutic strategies on LV performance.


    Footnotes
 
The online-only Data Supplement is available with this article at http://circ.ahajournals.org/cgi/content/full/1/1/41/DC1.


Related Article

Tomographic Left Ventricular Volumetric Emptying Analysis by Real-Time 3-Dimensional Echocardiography: Influence of Left Ventricular Dysfunction With and Without Electrical Dyssynchrony
Stefano De Castro, Francesco Faletra, Emanuele Di Angelantonio, Cristina Conca, Andrea Marcantonio, Marco Francone, Domenico Cartoni, Francesca Mirabelli, Carlo Gaudio, Stefano Caselli, Iacopo Carbone, Angelo Auricchio, and Natesa G. Pandian
Circ Cardiovasc Imaging 2008 1: 41-49. [Abstract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
J Am Coll Cardiol ImgHome page
M. Monaghan, J. Bax, A. Franke, O. Kamp, H. Kuehl, P. Nihoyannopoulos, and F. TenCate
3-Dimensional Echocardiographic Assessment of Left Ventricular Dyssynchrony: An Alternative Viewpoint
J. Am. Coll. Cardiol. Img., November 1, 2009; 2(11): 1334 - 1335.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Castro, S.
Right arrow Articles by Pandian, N. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Castro, S.
Right arrow Articles by Pandian, N. G.
Related Collections
Right arrow Other heart failure
Right arrow CT and MRI
Right arrow Echocardiography
Right arrowRelated Article