Editorial |
From the Medical Research Council Clinical Sciences Centre (P.G.C., O.E.R.) and the National Heart and Lung Institute (P.G.C., O.E.R.), Imperial College, London, United Kingdom; and Consiglio Nazionale delle Ricerche (O.E.R.), Institute of Clinical Physiology, Pisa, Italy.
Correspondence to Paolo G. Camici, MD, MRC Clinical Sciences Centre, Hammersmith Hospital, Du Cane Road, London W12 0NN, United Kingdom. E-mail paolo.camici@csc.mrc.ac.uk
Key Words: Editorials imaging
An extract of the first 250 words of the full text is provided, because this article has no abstract. |
Currently, nuclear imaging techniques can be used to diagnose coronary macrovascular and microvascular disease and to measure infarct size and left ventricular ejection fraction. Semiquantitative assessment of regional myocardial perfusion with single-photon emission computed tomography is a noninvasive, robust, and widely available method of assessing myocardial ischemia and has an established role in the clinical setting.1 A great number of studies have assessed the sensitivity and specificity of this technique for the detection of coronary artery disease (CAD), with coronary arteriography usually being used as the standard by which the accuracy of scintigraphy is judged.1 The main limitation of single-photon emission computed tomography perfusion imaging is that it provides only semiquantitative information on the regional distribution of myocardial blood flow (MBF). This is particularly relevant in conditions in which MBF and coronary flow reserve (CFR) are diffusely abnormal, (eg, in patients with hypertrophic and dilated cardiomyopathies).2
Article p 77
The ability to make quantitative measurements of MBF with positron-emission tomography (PET) allows determination of the functional significance of epicardial coronary lesions. In patients with single-vessel CAD, chronic stable angina, and no previous history of myocardial infarction (MI), CFR in response to a standard dose of dipyridamole was found to be markedly reduced in the myocardial regions subtended by the stenosed coronary artery compared with regions subtended by angiographically normal vessels.3 Using H215O or 13NH3 with PET, the relationship between stenosis severity, measured by quantitative coronary angiography, and its consequences on regional MBF and CFR has been described.4,5 Furthermore, the
Related Article
Circ Cardiovasc Imaging 2009 2: 77-84.
|
Home | Subscriptions | Archives | Feedback | Authors | Help | Circulation Journals Home | AHA Journals Home | Search Copyright © 2009 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |