Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation: Cardiovascular Imaging
Search: search_blue_button Advanced Search
Circulation: Cardiovascular Imaging. 2008;1:104-113
Published online before print July 30, 2008, doi: 10.1161/CIRCIMAGING.108.768911
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1/2/104    most recent
CIRCIMAGING.108.768911v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burman, E. D.
Right arrow Articles by Kilner, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burman, E. D.
Right arrow Articles by Kilner, P. J.
Related Collections
Right arrow CT and MRI
Right arrow CV surgery: valvular disease

Original Articles

Aortic Root Measurement by Cardiovascular Magnetic Resonance

Specification of Planes and Lines of Measurement and Corresponding Normal Values

Elisabeth D. Burman, MSc; Jennifer Keegan, PhD and Philip J. Kilner, MD, PhD

From the Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom.

Correspondence to Elisabeth Burman, CMR Unit, Royal Brompton Hospital, Sydney Street, London SW3 6NP, United Kingdom. E-mail e.burman{at}rbht.nhs.uk

Received February 14, 2008; accepted July 9, 2008.

Background— Cardiovascular magnetic resonance is widely used for aortic root visualization and measurement, but methods still need to be standardized. Our aim was to identify appropriate planes of acquisition and lines of measurement and record corresponding normal values.

Methods and Results— We studied 120 healthy volunteers, 10 of each gender in each decile between 20 and 80 years, by using a 1.5-T cardiovascular magnetic resonance system. Steady-state free precession cine acquisitions aligned with the left ventricular outflow tract in oblique sagittal and coronal orientations were used to locate 2 sinus planes that transected the root at its widest point in its maximally expanded systolic and at its end diastolic positions. We measured the cusp-cusp and the cusp-commissure dimensions in these cine planes, each as the average of 3. Diastolic cusp-commissure dimensions were smaller than diastolic cusp-cusp dimensions (32.0±3.5 mm versus 34.6±4.0 mm in men, 28.4±2.8 mm versus 30.7±3.3 mm in women, P<0.001 for both). The diastolic cusp-commissure dimensions increased by 0.9 mm per decade in men and 0.7 mm per decade in women (P<0.001 for both) and gave higher R2 values with respect to age and body surface area (0.40 for men, 0.27 for women) than diastolic cusp-cusp, systolic cusp-commissure, or sinus measurements made in the left ventricular outflow tract planes.

Conclusions— The results indicate the importance of consistent methods for measurement of the aortic root by cardiovascular magnetic resonance. We recommend diastolic cusp-commissure measurements, which yielded favorable R2 values with respect to age and body surface area and were found to correspond closely with reference echocardiographic root measurements recorded in the Framingham cohort. We recorded reference values for these and other possible aortic root measurements by cardiovascular magnetic resonance.

Key Words: aorta • valves • magnetic resonance imaging